CP Series There are 17 products.

  • CPU
    CPU

    - Easily find errors with the self-diagnosis program- Maximum base expansion: 16 (except CP4)- Additional integrated communication port - (CM1-CP4C:RS232C, CM1-CP4D/U:RS422/485)- In the event that the CPU is replaced, - I/O and base specifications are still maintained- Various program types- Supports over 300 instructions- Built-in USB 2.0 port (CP4U / CP3U only)- Attachable flash memory for flexibility (CP3P only)- Built-in loader port for...

    - Easily find errors with the self-diagnosis program- Maximum base expansion: 16...

    - Easily find errors with the self-diagnosis program- Maximum base expansion: 16 (except CP4)- Additional integrated communication port - (CM1-CP4C:RS232C,...

  • Power
    Power

    - The power supply for CIMON PLC XP/CP Series(AC100-240V convert to DC +5V, +24V, +15V, -15V)- Internal power disturbance monitoring function prevents data damage or system malfunctions

    - The power supply for CIMON PLC XP/CP Series(AC100-240V convert to DC +5V, +24V, +15V,...

    - The power supply for CIMON PLC XP/CP Series(AC100-240V convert to DC +5V, +24V, +15V, -15V)- Internal power disturbance monitoring function prevents data damage or system...

  • Digital I/O
    Digital I/O

    - Photo-coupler insulation and relay insulation- LED display to monitor running conditions- Terminal block type: Easy maintenance and installation

    - Photo-coupler insulation and relay insulation- LED display to monitor running...

    - Photo-coupler insulation and relay insulation- LED display to monitor running conditions- Terminal block type: Easy maintenance and installation

  • Analog I/O
    Analog I/O

    - 4, 8, or 16 channels of A/D conversion with one module- Voltage or current input can be selected from each channel (CM1-AD04VI only)- High resolution of 1/64000 (CM1-AD04W only) and 1/16000

    - 4, 8, or 16 channels of A/D conversion with one module- Voltage or current input can...

    - 4, 8, or 16 channels of A/D conversion with one module- Voltage or current input can be selected from each channel (CM1-AD04VI only)- High resolution of 1/64000 (CM1-AD04W...

  • Load Cell Module
    Load Cell Module

    -2 or 4 channels per module-The unit is compatible with various applicable fields such asUnload Scale,Bin Scale,Mixing Scale,Filling Scale(packaging)-24 bit sigma delta AD conversion provides high resolution digital values-Supports built-in programs such as input and discharge measurement-WG02C model can be in dynamic measurement by getting external 24V DI input

    -2 or 4 channels per module-The unit is compatible with various applicable fields such...

    -2 or 4 channels per module-The unit is compatible with various applicable fields such asUnload Scale,Bin Scale,Mixing Scale,Filling Scale(packaging)-24 bit sigma delta AD...

  • Data Logger
    Data Logger

    -Large capacity with non-combustible log memory(32MB)-Real time data stampling & saving-Acquiers the stored data anytime from SCADA when the communication status returns to normal-Simultaneously samples data with a maximum of 32 word and a maximum perido of 10ms-Built in HMI protocol: no operation communication card needed-Self-diagnostic function: communication error,memory error,capacity check,etc.-Triggers logging by Sequence...

    -Large capacity with non-combustible log memory(32MB)-Real time data stampling &...

    -Large capacity with non-combustible log memory(32MB)-Real time data stampling & saving-Acquiers the stored data anytime from SCADA when the communication status returns to...

  • Positioning
    Positioning

    -Enable to set maximum of 600 positing data-Features position control and speed control-Positing control of one axis: linear interpolation,separate/synchronous operation-Positing control of two axes: speed control, arc/linear/interpolation, separate/synchronous operation

    -Enable to set maximum of 600 positing data-Features position control and speed...

    -Enable to set maximum of 600 positing data-Features position control and speed control-Positing control of one axis: linear interpolation,separate/synchronous...

  • HSC(High Speed Counter Module)
    HSC(High Speed Counter...

    -1-Phase input: Up/Down count by a program or B-phase-2-Phase input: Up/Down count by Phase difference-Adding and substract function for 2-phase input-Preset function by extarnal input signal or a program-Outputs compresion signal by comparing the best value and the current value throught the built-in transistor-Enables ring counting,sampling,sampling counting,periodic pulse counting and latch function

    -1-Phase input: Up/Down count by a program or B-phase-2-Phase input: Up/Down count by...

    -1-Phase input: Up/Down count by a program or B-phase-2-Phase input: Up/Down count by Phase difference-Adding and substract function for 2-phase input-Preset function by...

  • BACnet
    BACnet

    -BACnet stands for Building Automation and Control Network-BACnet is applicable to various building utilities such as HVAC control system,lighting control system,security system,elevator control system etc-Easy to modify and expand due to use of standard protocl-Supports BACnet which is the standard of building automation system-Supports functionality BACnet class 3 servers-Uses Ethernet for communcaction physical layer (BACnet IP)

    -BACnet stands for Building Automation and Control Network-BACnet is applicable to...

    -BACnet stands for Building Automation and Control Network-BACnet is applicable to various building utilities such as HVAC control system,lighting control system,security...

  • Profibus
    Profibus

    Profibus is an open-type fieldbus witch is universally for automation and enablesseamless communcation beteween different manufacture's device.As technology advance, Profibus is the industrial communication system that will be ready for the future.

    Profibus is an open-type fieldbus witch is universally for automation and...

    Profibus is an open-type fieldbus witch is universally for automation and enablesseamless communcation beteween different manufacture's device.As technology advance, Profibus is...

  • CIMON-NET
    CIMON-NET

    CIMON-NET exchange real time date write Remote I/O through the CANbus hardware witch provides excepional reliability

    CIMON-NET exchange real time date write Remote I/O through the CANbus hardware witch...

    CIMON-NET exchange real time date write Remote I/O through the CANbus hardware witch provides excepional reliability

  • Serial Communication
    Serial Communication

    -Possibile to read and write DATA by HMI protocols-Maximum 32 unit communication available for multi-drop configuration-Long distance communication via modem connection-Various communcation speed(300dps~76800dps)-Various diagnostic function with Loop-Back feature makes for an easy error check-RS232C/RS422(RS485) communication port by setting up independent channel or linked channel-1:1/1:N/N:M communication (RS5485)-Full-Duplex(RS422) and...

    -Possibile to read and write DATA by HMI protocols-Maximum 32 unit communication...

    -Possibile to read and write DATA by HMI protocols-Maximum 32 unit communication available for multi-drop configuration-Long distance communication via modem connection-Various...

  • Ethernet
    Ethernet

    -Standard IEEE 802.3-Various protocols(ARP,ICMP,IP,TCP,UDP)-Ethernet communication modules cab be installed in one base with no limitation-High Speed linkage to simultaneosuly communicate-Along CIMON PLC's and up to 64-stations DNP 3.0 protocols(CM1-EC01DNP,CM1-EC04DNP)

    -Standard IEEE 802.3-Various protocols(ARP,ICMP,IP,TCP,UDP)-Ethernet communication...

    -Standard IEEE 802.3-Various protocols(ARP,ICMP,IP,TCP,UDP)-Ethernet communication modules cab be installed in one base with no limitation-High Speed linkage to simultaneosuly...

  • Base
    Base

    The Base is used with XP and CP series

    The Base is used with XP and CP series

    The Base is used with XP and CP series